iio: dac: ad3552r-common: fix ad3541/2r ranges
Fix ad3541/2r voltage ranges to be as per ad3542r datasheet,
rev. C, table 38 (page 57).
The wrong ad354xr ranges was generating erroneous Vpp output.
In more details:
- fix wrong number of ranges, they are 5 ranges, not 6,
- remove non-existent 0-3V range,
- adjust order, since ad3552r_find_range() get a wrong index,
producing a wrong Vpp as output.
Retested all the ranges on real hardware, EVALAD3542RFMCZ:
adi,output-range-microvolt (fdt):
<(000000) (
2500000)>; ok (Rfbx1, switch 10)
<(000000) (
5000000)>; ok (Rfbx1, switch 10)
<(000000) (
10000000)>; ok (Rfbx1, switch 10)
<(-
5000000) (
5000000)>; ok (Rfbx2, switch +/- 5)
<(-
2500000) (
7500000)>; ok (Rfbx2, switch -2.5/7.5)
Fixes: 8f2b54824b28 ("drivers:iio:dac: Add AD3552R driver support")
Signed-off-by: Angelo Dureghello <adureghello@baylibre.com>
Reviewed-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/20250108-wip-bl-ad3552r-axi-v0-iio-testing-carlos-v2-1-2dac02f04638@baylibre.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>